Description
Low hydrogen T-8 self-shielded, all positional flux cored wire, producing a stable arc and flat bead profile, especially suited for vertical-up welds at high currents with excellent mechanical properties and a tensile strength of 490 MPa.
Capable of depositing X-ray quality welds, making it highly suitable for critical welding applications requiring a high degree of crack resistance due to its low diffusible hydrogen levels, less than 6.7ml per 100g of weld metal deposited.
XLR-8 has been designed for single and multi-pass welding applications with improved productivity in out-of-position welding, offering high impact strength of 42J at sub zero temperatures to -40°C.
Typical Applications:
Specifically designed for increased productivity and high deposition rates on challenging structural steel erection, heavy equipment repair, mining equipment, bucket repairs, storage tanks, pipe spooling, ship construction and site work applications.
Applications:
- Structural Steel Erection
- Storage Tanks
- Site Work Applications
- Ship Construction
- Pipe Spooling
- Mining Equipment
- Heavy Equipment Repair
- Bucket Repairs
Processes:
- FCAW-S
Classification:
- AS/NZS IS0 17632-B – T492T8-1NA-U H10
- AWS A5.20: E71T-8JD H8
Specifications:
Typical All Weld Metal Chemical Analysis
- C: 0.19
- Mn: 0.51
- Si: 0.17
- P: 0.009
- S: 0.009
- AI: 0.51
- Fe: Bal
Typical All Weld Metal Mechanical Analysis
- Yield Strength: 469 MPa
- Tensile Strength: 579 MPa
- Elongation: 28%
- CVN Impact Values: 68J @ -20ºC, 54J @ -30ºC, 42J @ -40ºC